EasyManuals Logo
Home>Haier>Air Conditioner>H2SM-(9+12)HEK03/R2

Haier H2SM-(9+12)HEK03/R2 User Manual

Haier H2SM-(9+12)HEK03/R2
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
H2SM-(9+12)HEK03/R2
Introduction
Domestic Air Conditioner
1
1. Introduction
1.1 Safety Cautions
Be sure to read the following safety cautions before conducting repair work.
The caution items are classified into “Warning” and “Caution”. The “Warning” items are especially
important since they can lead to death or serious injury if they are not followed closely. The “Caution”
items can also lead to serious accidents under some conditions if they are not followed. Therefore, be
sure to observe all the safety caution items described below.
About the pictograms
U
This symbol indicates an item for which caution must be exercised.
The pictogram shows the item to which attention must be paid.
c
This symbol indicates a prohibited action.
The prohibited item or action is shown inside or near the symbol.
z
This symbol indicates an action that must be taken, or an instruction.
The instruction is shown inside or near the symbol.
After the repair work is complete, be sure to conduct a test operation to ensure that the equipment
operates normally, and explain the cautions for operating the product to the customer.
1.2 Caution in Repair
Warning
Be sure to disconnect the power cable plug from the plug socket before disassembling the
equipment for a repair.
Working on the equipment that is connected to a power supply can cause an electrical
shook.
If it is necessary to supply power to the equipment to conduct the repair or inspecting the
circuits, do not touch any electrically charged sections of the equipment.
If the refrigerant gas discharges during the repair work, do not touch the discharging
refrigerant gas.The refrigerant gas can cause frostbite.
When disconnecting the suction or discharge pipe of the compressor at the welded section,
UHOHDVHWKHUHIULJHUDQWJDVFRPSOHWHO\DWDZHOOYHQWLODWHGSODFH¿UVW
If there is a gas remaining inside the compressor, the refrigerant gas or refrigerating
machine oil discharges when the pipe is disconnected, and it can cause injury.
If the refrigerant gas leaks during the repair work, ventilate the area. The refrigerant gas can
JHQHUDWHWR[LFJDVHVZKHQLWFRQWDFWVÀDPHV
The step-up capacitor supplies high-voltage electricity to the electrical components of the
outdoor unit.
Be sure to discharge the capacitor completely before conducting repair work.A charged
capacitor can cause an electrical shock.
Do not start or stop the air conditioner operation by plugging or unplugging the power cable
plug.
Plugging or unplugging the power cable plug to operate the equipment can cause an
HOHFWULFDOVKRFNRU¿UH