SCPI Programming Reference
HDG2000 Series Arbitrary Waveform Generator 92
Set smask
Parameter
Typical Return
0.0.0.0 to 255.255.255.255
Smask: nnn.nnn.nnn.nn
Set smask to 192.168.1.118: SYSTem:COMMunicate:LAN:IPADdres 192.168.1.118
SYSTem:ERRor?
Reads and clears one error from error queue.
Parameter
Typical Return
none
-113, "Undefined header; keyword cannot be
found";
No error: 0, "No Error"
Read and clear first error in error queue: SYST:ERR?
SYSTem:LANGuage ENGLish|SCHineseSYSTem:LANGuage?
Set language to English or SCHinese.
Parameter
Typical Return
ENGLish|SCHinese, default ENGLish
ENGLish, or SCHinese
Set language to SChinese: SYSTem:LANGuage SCHinese
SYSTem:KLOCk ON|OFF
SYSTem:KLOCk?
Remotely enable or disable front-panel keyboard.
Parameter
Typical Return
ON|OFF, default OFF
ON, or OFF
Disable front-panel keyboard: SYSTem:KLOCk ON
SYSTem:VERSion?
Find and return SCP version information
Parameter
Typical Return
none
Return SCPI information
Find and return SCP version information: SYSTem:VERSion?
5.2.27 VOLTage Subsystem
The VOLTage subsystem sets parameters related to output voltage.
SOURce<n>:VOLTage <amplitude>|MINimum|MAXimum
SOURce<n>:VOLTage? [{MINimum|MAXimum}]
Sets output amplitude.