Harman® • Accentra Owner’s Manual_R40 • 2002 -___ • 11/1523 3-90-08326c
C. Loss of Power
Minimizing Smoke During Loss of Power Using Battery
Back-up
Harman® strongly recommends installing battery back-
up to minimize entry of smoke into the room in the
event of power loss.
Your pellet/biomass burning appliance relies on a
combustionblowertoremoveexhaust.Apowerfailurewill
cause the combustion blower to stop. This may lead to
exhaustseepingintotheroom.Verticalriseintheventing
may provide natural draft. It is, however, no guarantee
againstleakage.
There are two Harman® approved battery back-up
options for your appliance:
Uninterruptible Power Supply UPSbatteryback-upsare
availableonlineoratcomputerandofceequipmentstores.
Your Harman® appliance with Rev E or later software
available beginning in November 2010 may be plugged
directlyintoaHarman®approvedUPS:
• The APC (American Power Conversion) model
#BE750GandtheTrippLitemodelINTERNET750Uare
testedandapproved.Otherbrandsormodelsmaynot
becompatible.
Whenpowerislost,afullychargedUPSwillpowerasafe,
combustion blower only shut-down. Your appliance will
pulsetheblowereveryfewsecondstoclearexhaustuntil
thereisout. NOTE: The UPS provides safe shut-down
only. It is not intended for continued operation.
• TheSurere512connectstoa12voltdeepcyclebattery
thatwillrunyourapplianceforup to eight (8) hours.It
includesatricklechargefeaturethatkeepsyourbattery
chargedwhenpowerisavailable.NOTE:Ifthepoweris
outforlongerthanbatterylife,smokeleakagemaystill
occurunlessyourstovehasbeensafelyshutdown.
Yourappliancewillrecognizewhenpowerisrestored.What
happens depends on ESP temperature and whether it is
equippedwithautomaticignition:
In “Automatic” Mode,units equipped with automatic
ignitionwillrespondtothesetpointandESPtemperature
andresumenormaloperation.
In “Idle” Mode,orforunitswithoutautomaticignition:
• If the ESP is cool, the appliance will remain shut
down.
• IfthereisoutandtheESPisstillwarm,thefeeder
mayrestart.Sincethereisout,theESPtemperature
willnotrise.Theunitwillthenshut-down,andmay
ashasix-blinkstatuserror.(SeeESPerrorcodes)
• If the re is still burning, it will resume normal
operation.
Contact your dealer if you have questions about UPS
compatibilitywithyourappliance.
Use only Harman
®
approved battery back-up devices.
Other products may not operate properly, can create
unsafe conditions or damage your appliance.
CAUTION
!
Always keep appliance doors and hopper lid closed
and latched during operation and during power
failures to minimize risk of smoke or burn-back.
D. Emergency Manual Ignition
Harman
®
pellet stoves and inserts should be lit using the
automatic ignition system. This is the safest and most
reliablewayforignitingtheunit.Intheeventtheautomatic
igniterisnotfunctioning,thestepsbelowmaybefollowed
tomanuallylightthestoveorinsertinthe“ConstantBurn”
mode. Manual lighting is for emergency purposes only,
andtheignitershouldberepairedorreplacedassoonas
practical.
WARNING
!
Only use restarter commercially marketed for pellet
stoves and inserts, including wax coated wood chips,
pellet starter gel and pellet igniter blocks. Use of any
othertypeofrestarterisprohibited.
To avoid serious injury or death read and follow
manufacturer’swarningandinstructionsforuseofrestarter.
Useofrestarterisonlypermittedwhenperformingacold
start.
Neverattempt to manuallylighta stove orinsert that has
been operated recently and is not at room temperature.
If automatic ignition was attempted, be sure to give the
stoveorinsertatleast30minutesorlongertocooltoroom
temperature.
Besurethatthestoveorinsertisinthe“Igniter-Disabled”
modeofoperation.
Once all the precautions have been taken, follow these
steps:
1.TurntheModeSelectorto“OFF”.
2.Fillburnpotwithpellets,onlyhalfway.(DoNotOverFill).
3.Add firestarter to pellets following manufacturer’s
instructions.
4. Lightpelletgelwithamatch,andclosethedoor,turnMode
SelectortoConstantBurn.Operationwillbeginwhenthe
rereachesthepropertemperature.
WARNING
!

Other manuals for Harman Accentra

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Harman Accentra and is the answer not in the manual?

Harman Accentra Specifications

General IconGeneral
BrandHarman
ModelAccentra
CategoryPellet stove
LanguageEnglish

Related product manuals