Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/1410
3-90-08121i
No Change of Combustion
Blower Fan Blade Needed
5 Ft
10 Ft
15 Ft
20 Ft
25 Ft
30 Ft
0 Ft
0 Ft5 Ft10 Ft15 Ft18 Ft 5 Ft 10 Ft 15 Ft 18 Ft
5 Ft
0 Ft
7 Ft
10
9
8
7
6
5
4
3
5 Ft
0 Ft
10 Ft
12 Ft
Combustion Blower Fan
Blade Changeover Line
A Change of the Combustion
Blower Fan Blade is Required
Part #3-20-502221
Note: The total Lineal Feet decreases as the
Altitude increases.
Note: The maximum length of the Outside Air
Flex also decreases to 20 Feet when the High
Altitude fan blade is used.
Total Lineal Feet combined should not exceed
30 Feet.
Altitude in thousands of feet.
B. Venting Conguration Graph
Figure 4.2
To reduce probability of reverse drafting during a
power failure, Hearth & Home Technologies strongly
recommends:
• Installingthepelletventwithaminimumverticalriseof
vefeet.Preferablyterminatingabovetheroofline.
• Installinganoutsideairconnectiontotheappliance.
To prevent soot damage to exterior walls, and to prevent
re-entry of soot or ash into the home:
• Maintainspeciedclearancestowindows,doorsandair
inlets,includingairconditioners.
• Ventsshouldnotbeplacedbelowventilatedsofts.
• Avoidventingintoalcovelocations.
• Vents should not terminateunderoverhangs, decks or
ontocoveredporches.
• Maintain minimum clearance of 12” from the vent
terminationtotheexteriorwall.
Hearth & Home Technologies assumes no responsibility
for, nor does the warranty extend to, smoke damage
caused by reverse drafting of pellet appliances under
power failure conditions.
Hearth&HomeTechnologiesstronglyrecommendstheuse
ofoutsideairforallpelletfurnaceapplications.
Per national building codes, consideration must be given
to combustion air supply for all appliances in the vicinity
ofthepelletboiler.Failuretosupplyadequatecombustion
airforallappliancedemandsmaylead to backdrafting of
thoseappliances.ConsultwithyourHVACProfessionalto
determinethatallcombustionairrequirementsaremet.
When the appliance is side-wall vented:Theairintakeis
bestlocatedonthesameexteriorwallas,andlowerthan
theexhaustventoutlet.
When the appliance is roof vented:Theairintakeisbest
locatedontheexteriorwallorientedtowardstheprevailing
winddirection,duringtheheatingseason.