C. Locating Your Appliance & Chimney
Locationoftheapplianceandchimneywillaffectperformance.
Figure4.3
• Installthroughthewarmairspaceenclosedbythebuilding
envelope.Thishelpsto produce more draft,especially
duringlightinganddie-downofthere.
• Penetratethehighestpartoftheroof.Thisminimizesthe
effectsofwindloading.
Locate termination cap away from trees, adjacent
structures,unevenrooflinesandotherobstructions.
• Minimizetheuseofchimneyoffsets.
• Considertheappliancelocationrelativetooorandceiling
andatticjoists.
• DONOTCONNECTTHISUNITTOACHIMNEYFLUE
SERVICINGANOTHERAPPLIANCE.
Mayallowuegasestoenterthehouse
CAUTION
!
Marginal Location:
Below peak
Location NOT recommended:
Not the highest point of the roof
Wind loading possible
Multi-level Roofs
Windward
Leeward
Recommended:
Outside Air Intake
on windward side
NOT recommended:
Outside Air Intake
on leeward side
Recommended Location:
Above peak
Recommended:
Insulated exterior chase
in cooler climates
Recommended Location:
Above peak
Inside heated space
Location NOT recommended:
Too close to tree
Below adjacent structure
Lower roof line
Avoid outside wall
Marginal Location:
Wind loading possible
Figure 4.3