Harman® • Owners anualR2 • 200 - • 0812 2 3 -9 0 -0 0 6 8 4 c
6
Troubleshooting and F req uently Asked Q uestions
Status light error messages:
3 Blinks: Indicates that the ESP (Exhaust Sensing Probe)
has failed, has a broken connection, or has gone out of range
too many times. This requires a manual reset.
4 Blinks: Can occur only in Room Temp ode and
indicates Room Sensing Probe failed or not installed. If a
Room Sensing Probe is then installed, the status light will
automatically reset.
NOTE: Unit will not start in AUTO with this status error.
5 Blinks (In Igniter Auto. Mode Only): Indicates that the unit
has failed to light within the minute start cycle. To reset -
Turn ode Selector to O, then turn to either mode again.)
6 Blinks : Indicates that the control has calculated poor or
incomplete combustion occurring for more than 25 minutes.
A six blink status may be set if the stove is allowed to run out
of pellets. To reset, turn mode selector to O then back
on to the desired mode. If the unit was not out of pellets, see
Troubleshooting section for more details.
* Manual reset- disconnect power cord for a few seconds
and reconnect. If error still occurs call your ealer.
A. Error Code Description