Problem Detected: LED #8 or MAX
LED #8 Flashing
(Low or no flow
condition)
YES
NO
Remove power
for 2 mins then
re-apply
NO
YES
MAX Flashing
(Water
Temperature
error)
Did error clear?
NO
Briefly turn on
Super Chlorinate
then turn back
off
YES
NO
YES
YES
NO
YES
YES
Does moving
water fully cover
cell plates?
Clean filter or
clear obstruction
in plumbing
NO
Remove power
for 2 mins then
re-apply
Is cell cable
secure and free
of damage?
Is the cable secure
and free of
damage?
YES
NO
NO
Problem solved
Did error clear?
Did error clear?
Did error clear?
Did error clear?
Problem solved
NO
YES
NO
*For verification of diagnosis contact Hayward Technical Support
908-355-7995
Replace PCB
(GLXAQR100PCB)
Replace Cell Cable
(GLXAQR100CABLE)
Replace Cell
(CCELL)
YES
Did error clear?
Replace Cell Cable
(GLXAQR100CABLE)
51