“SF” OR
“HS” Code
Check display for
SF” code
Is “SF” code
present?
The “HS” code
stands for High
Sense (water
temperature).
YES
NO
Ohm thermistor,
checking each red to
black, do the readings
differ by more than 1°?
40
Replace
thermistor:
FDXLTER1930
YES
NO
8. Service LED ON: “SF” OR “HS” Code
Replace ICB:
FDXLICB1930
Make sure water
inlet & outlet are
plumbed correctly,
are they reversed?
YES
Plumb correctly in
compliance with
installation manual
NO
Ohm thermistor,
checking each red to
black, do the readings
differ by more than 1°?
NO
Replace ICB:
FDXLICB1930
Replace
thermistor:
FDXLTER1930
YES

Other manuals for Hayward H400FDN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hayward H400FDN and is the answer not in the manual?

Hayward H400FDN Specifications

General IconGeneral
TypeNatural Gas
BTU Input400, 000 BTU
Pool TypeIn-ground
Heat ExchangerCupro Nickel
Voltage120V
Efficiency84%
Water Flow Rate40-120 GPM
Inlet/Outlet Size2 in