Incorrect installation:
It’s important to keep the exhaust pipe smooth, and with no bends. Incorrect mounting can contribute to
the efficiency of the air conditioner. Ensure that the air can flow freely through the pipe.
Warning: The exhaust pipe is designed especially for this model. Do not replace or lengthen it; otherwise it
will result in failure.
Note: Maximum length of the exhaust pipe is 1500mm. It’s better to keep it the shortest length possible and
keep it horizontal.
Operation
Cooling mode
When the A/C enters cooling mode after it’s turned on, the cooling indicator will light up.
Press the Up/Down button to adjust the temperature (17°-30°).
Press the Speed button to choose High/Low fan speed.
Fan mode
When pressing the mode button or choosing the fan mode by pressing the remote control, the wind
indicator will light up.
Press the Speed button to choose High/Low fan speed.
Temperature cannot be set when fan mode is selected.
Dehumidifying mode
When pressing the mode button or choosing the dehumidifying mode by
pressing the remote control, the dehumidifying indicator will light up.
Remove the dehumidification water drainage nozzle, insert the water pipe,
and place the other end of the water pipe into the water vessel (bucket not
supplied) or into a drainage passage, as shown in the right figure.
After entering the dehumidifying mode, if the room temperature is more
than 15°, the compressor will work. When room temperature is less than 13°,
the compressor switches OFF; when the temperature increases to more than
15°, the compressor will restart (in order to protect the compressor, it will
restart 3 minutes later).
In dehumidifying mode, the fan is defaulted to run at low speed, and the fan
speed cannot be adjusted.
Temperature cannot be set.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HELLER HPAC12 and is the answer not in the manual?

HELLER HPAC12 Specifications

Operating Pressure IconOperating Pressure
permissible excessive operating pressure (suction)1.0 MPa
permissible excessive operating pressure (discharge)3.5 MPa
maximum allowable pressure (low pressure side)1.7 MPa
maximum allowable pressure (high pressure side)5.5 MPa
Performance IconPerformance
cooling capacity3.5 kW
air flow420 m3/h
noise55 dB(A)
rated input (cooling)1450 W
Refrigerant IconRefrigerant
refrigerant typeR410a
refrigerant charge565 g
Power Supply IconPower Supply
power supply voltage220-240 V
power supply frequency50 Hz
fuse voltage250 VAC
Weight and Dimensions IconWeight and Dimensions
net weight28.5 kg
gross weight33 kg
dimensions (WxHxD)443x830x340 mm