Figure 4-5 Flush Mounng with Juncon Box
4.1.5 Flush Mounng with Gang Box(Type I)
The device supports ush mounng with gang box.
Before You Start
Make sure all related equipments are
power-o during the installaon.
Accessories that you need to prepare for
installaon: Gang box and mounng
plate.
Tools that you need to prepare for
installaon: Drill (ø2.846) and gradienter.
Purchase the protecve shield before installaon.
Steps
1. Cave the installaon hole in the wall.
Note
The dimension of the installaon hole should be larger than the gang box.
2. Insert the gang box to the hole chiseled on the wall.
3. Fix the
mounng plate to the gang box with 2 screws.
Note
The dimension of the gang box is 75mm(width) × 75 mm(length) × 46 mm(depth),
the le and right holes will be applies.