-Stay Arm Delay Time: Stay arming uses Stay Arm Delay Time to count down.
The system gives Entry/Exit delay time when it is armed or reentered. It is usually used in
entrance/exit route (e.g. front door/main entrance), which is a key route to arm/disarm via
operating keypad for users.
Note
You can set 2 different time durations in System Options Schedule & Timer.
Ensure that timer is no longer than 45 seconds in order to comply with EN50131-1.
You can set Stay Arm Delay Time for the delay zone.
Panic Zone
24-hour active zone, whether armed or not. Report panic alarm after triggering. It is usually
used in the sites equipped with panic button, smoke detector and glass-break detector.
Medical Alarm
24-hour active zone, whether armed or not. Report medical alarm after triggering.
Fire Zone
24-hour active zone, whether armed or not. Report fire alarm after triggering.
Gas Zone
24-hour active zone, whether armed or not. Report gas alarm after triggering.
Follow Zone
The zone acts as delayed zone when it detects triggering event during system Entry Delay,
while it acts as instant zone otherwise.
Keyswitch Zone
-By Trigger Time: Change the arming and disarming status after each trigger. For example, in
the disarmed status, if the zone is triggered, the linked area will be armed. Trigger the zone
again and the area will be disarmed.
-By Zone Status: You need to choose to arm or disarm the linked area after the zone is
triggered.
In the case of the tampering alarm, the arming and disarming operation will not be triggered.
Disabled Zone
Zone disabled ignoring any alarm event. It is usually used to disable faulty detectors.
24-hour Zone
The zone activates all the time with sound/light output when alarm occurs, whether it is
armed or not. It is usually used in fire hazardous areas equipped with smoke detectors and
temperature sensors.
Timeout Zone

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-PHA48-EP and is the answer not in the manual?

HIKVISION DS-PHA48-EP Specifications

General IconGeneral
2G standardsGSM
Number of alarm zones48
Alert notification typeSMS
Connectivity technologyWired & Wireless
Mobile network generation4G
Smartphone remote supportYes
Number of simultaneous users48 user(s)
Control type-
Mounting typeWall
Product colorWhite
Housing materialPlastic
Number of door/window sensors- pc(s)
Battery life36 h
Input voltage100 - 240 V
Battery voltage13.5 V
Battery capacity7000 mAh
Weight and Dimensions IconWeight and Dimensions
Alarm control panel weight996.5 g
Alarm control panel dimensions (W x D x H)261 x 86.4 x 261 mm