6.8 Sensor
6.8.1 Measuring the sensor resistance
Use a multimeter with the ohm switch to measure the resistor of sensor.
You'd better measure the following temperature resistance is more accurate, and more likely
to get the temperature. Normally at surrounding -18
,5
,25
, the corresponding
resistance is about 17kohm,5kohm,2kohm. If the measured value is not within the normal
scope, the sensor is bad and needs to repair or change.
Picture1
-Models with ice maker Picture2-Models without ice maker
6.9 Door switch
1. Check the connecting wiring of door switch is well or not, repair if it is broken
Models with
ice maker
Picture 1
.
The fridge door switch corresponding pin No.4 and No.6 on 15 pins connector of main
control board.
The freezer door switch corresponding pin No.4 and No.7 on 15 pins connector of main
control board.
2. Check the connecting wiring of door switch is well or not, repair if it is broken
Models

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hisense RD-60WC1STA/USE-002 and is the answer not in the manual?

Hisense RD-60WC1STA/USE-002 Specifications

General IconGeneral
BrandHisense
ModelRD-60WC1STA/USE-002
CategoryRefrigerator
LanguageEnglish

Related product manuals