EasyManuals Logo
Home>Hitachi>Inverter>S1 Series

Hitachi S1 Series User Manual

Hitachi S1 Series
235 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
S1 series standard inverter
-9-
R
S
T
U
V
W
+
-
PE PE
PB
DC reactor
Fig 3.4 400V (18.5kW110kW) main circuit diagram
R
S
T
U
V
W
+
-
DC reactor
P1
PE PE
Fig 3.5 400V (132kW and above) main circuit diagram
Note:
1. 132kW and above inverters can be connected to external DC reactors. Before connection, it is
required to take off the copper bar between P1 and (+). 132kW and above inverters can be
connected to external brake unit. DC reactors and brake units are optional parts.
2. 18.5kW110kW inverters are equipped with built-in DC reactor.
3. 37kW and below models carry built-in brake units, 45kW55kW supports built-in brake unit.
75kW400kW supports external brake unit. The models that carry built-in brake unit can also be
connected to external brake resistor. The brake resistor is optional part.
3.3 Product specification
Function description
Specification
Power input
Input voltage (V)
AC 1PH 220V (-15%)240V (+10%) rated voltage: 230V
AC 3PH 380V (-15%)440V (+10%) rated voltage: 400V
Input current (A)
Refer to Rated value
Input frequency (Hz)
50Hz or 60Hz, allowable range: 4763Hz
Power
output
Output voltage (V)
0input voltage
Output current (A)
Refer to Rated value