SJ200 Inverter
xiii
Terminal Tightening Torque and Wire Size
The wire size range and tightening torque for field wiring terminals are presented in the
tables below.
Wire Connectors
WARNING: Field wiring connections must be
made by a UL Listed and CSA Certified ring lug
terminal connector sized for the wire gauge being
used. The connector must be fixed using the
crimping tool specified by the connector
manufacturer.
Input
Voltage
Motor Output
Inverter Model
Power Terminal
Wiring Size
Range (AWG)
Torque
kW HP ft-lbs (N-m)
200V
0.2 1/4 SJ200-002NFEF/NFU
16 0.6 0.80.4 1/2 SJ200-004NFEF/NFU
0.55 3/4 SJ200-005NFEF
0.75 1 SJ200-007NFEF/NFU
14
0.9 1.2
1.1 1 1/2 SJ200-011NFEF
1.5 2 SJ200-015NFEF/NFU 12
2.2 3 SJ200-022NFEF/NFU 10
3.7 5 SJ200-037LFU 12
5.5 7 1/2 SJ200-055LFU 10
1.5 2.0
7.5 10 SJ200-075LFU 8
400V
0.4 1/2 SJ200-004HFEF/HFU
16
0.9 1.2
0.75 1 SJ200-007HFEF/HFU
1.5 2 SJ200-015HFEF/HFU
2.2 3 SJ200-022HFEF/HFU
3.0 4 SJ200-030HFEF
14
4.0 5 SJ200-040HFEF/HFU
5.5 7 1/2 SJ200-055HFEF/HFU
12 1.5 2.0
7.5 10 SJ200-075HFEF/HFU
Terminal Connector
Wiring Size
Range (AWG)
Torque
ft-lbs (N-m)
Logic and Analog connectors 30—16 0.16—0.19 0.22—0.25
Relay connector 30—14 0.37—0.44 0.5—0.6
Cable
Terminal (ring lug)
Cable support

Table of Contents

Other manuals for Hitachi SJ200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi SJ200 Series and is the answer not in the manual?

Hitachi SJ200 Series Specifications

General IconGeneral
BrandHitachi
ModelSJ200 Series
CategoryInverter
LanguageEnglish

Related product manuals