EasyManuals Logo

Hitachi SJ200 Series User Manual

Hitachi SJ200 Series
276 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #249 background imageLoading...
Page #249 background image
SJ200 Inverter
Appendix B
B–35
Note 1: Assume that the inverter current rating is 10000 (for B013/B213).
B130 Over-voltage
LADSTOP enable
R/W Pauses deceleration ramp when
DC bus voltage rises above
threshold level, in order to
avoid over-voltage trip.
Two option codes:
00...Disable
01...Enable
00A4h 0, 1
B140 Over-current trip
suppression
R/W Two option codes:
00...Disable
01...Enable
00A5h 0, 1
B150 Carrier mode (not
accessible to ModBus)
Automatically reduces the
carrier frequency as the
ambient temperature increases.
Two option codes:
00...Disable
01...Enable
00A6h 0, 1
“B” Group Fine Tuning Functions
Func.
Code
Name R/W Description
Network Data
Reg. Range Res.

Table of Contents

Other manuals for Hitachi SJ200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi SJ200 Series and is the answer not in the manual?

Hitachi SJ200 Series Specifications

General IconGeneral
SeriesSJ200
CategoryInverter
Output Frequency0.1 to 400 Hz
Overload Capacity150% for 60 seconds
Cooling MethodFan cooled
Humidity5 to 95% RH (non-condensing)
Control MethodV/f Control, Sensorless Vector Control
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheat
Ambient Temperature-10 to 50°C
Braking UnitBuilt-in
CommunicationRS-485 (Modbus RTU)
AltitudeUp to 1000m
Output Voltage3-Phase 200-240 VAC, 3-Phase 380-480 VAC
Storage Temperature-20 to +60°C (-4 to 140°F)