SIM code list for troubleshooting by users
The following table lists and describes SIM codes that require action or restoration by
users. xxx in the following table indicates the port number.
If you select Host Report for Notication Alert in the Set Up Alert Notications
window, alert notication for SIMs that are reported to the host is sent. If you select All,
alert notication for all SIMs is sent.
Reference
code Failure
Alert level
(Severity)
Host
report
Reference
document
602xxx Pool blocking DKC
environment
MODERATE Yes Thin Image
602e Pools blocking by SM
volatile
DKC
environment
MODERATE Yes Thin Image
603000 SM Space Warning DKC
environment
MODERATE Yes Thin Image
604xxx Exceeded Threshold of
actual pool use rate
DKC
environment
MODERATE Yes Thin Image
605xxx Actual pool use rate
reaches upper limit
DKC
environment
MODERATE Yes Thin Image
606xxx Exceeded Fixed outage
Threshold of pool use
rate
DKC
environment
MODERATE Yes Thin Image
624000 SM Full DKC
environment
MODERATE Yes Provisioning
627xxx The DP POOL LDEV
blockade
DKC
environment
SERIOUS Yes Provisioning
628000 DP Protect attribute
setting of DRU
DKC
environment
SERIOUS Yes Provisioning
629xxx Exceeded Warning
Threshold of DP pool use
rate
DKC
environment
MODERATE Yes Provisioning
62axxx Actual DP pool use rate
reaches upper limit
DKC
environment
MODERATE Yes Provisioning
62b000 Threshold of DP pool use
rate remains exceeded
DKC
environment
MODERATE Yes Provisioning
SIM code list for troubleshooting by users
Chapter 2: SIM code lists
SIM Reference Guide for VSP E Series, and VSP G130, G/F350, G/F370, G/F700, G/F900 11