30
Parallel operation
Substantial overloading that continuously lights the Overload
indicator (red) may damage the generator. Marginal overloading that
temporarily lights the Overload indicator (red) may shorten the
service life of the generator.
Please read the item ‘‘GENERATOR USE’’ before connecting any
equipment to be used.
Use only a Honda approved receptacle box for parallel operation
(optional) when connecting two EU20i generators for parallel
operation.
Make sure that the electrical rating of the tool or appliance does not
exceed that of the generator. Never exceed the maximum power
rating of the generator. Power levels between rated and maximum
may be used for no more than 30 minutes.
Limit operation requiring maximum power to 30 minutes.
Maximum power in parallel operation is:
For continuous operation, do not exceed the rated power.
Rated power in parallel operation is:
In either case, the total power requirements (VA) of all appliances
connected must be considered
.
3.6kVA
4.0kVA
3.2kVA
Except U type :
U type :

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honda EU20I and is the answer not in the manual?

Honda EU20I Specifications

General IconGeneral
ModelEU20i
TypeInverter
EngineHonda GX100
Starting SystemRecoil
Noise Level at 1/4 Load53 dB(A)
Weight21 kg
InverterYes
Maximum AC Output2000 VA
Rated AC Output1600W
Displacement98.5 cm³
AC Output230V
DC Output12V, 8A