Terminals
Terminals Fire Panels
8 4188-424 issue 4_Part 1_10-09
Zones
FIRE
Faults
System
Power
Earth
Sounder
Disabled
Sound
Alarms
Silence
Alarms
1
23
4
56
7
8
9
0
v
Tes t
Access /
Function
1 2 3 4 5 6 7 8
Cancel
Buzzer
Reset
System
CN5 CN6 CN7 CN8 CN9 CN10 CN11 CN12 CN13 CN14 CN15 CN16 CN17 CN18 CN19 CN20 CN21 CN22 CN23 CN24 CN25 CN26 CN27 CN28CN29 CN30
F1 F2 F3 F4 F5 F6 F7 F8
F9 F10 F11
SECTOR1 SECTOR2 SECTOR 3 SECTOR4 SECTOR5 SECTOR6 SECTOR 7 SECTOR8BATTERIES
T1A T1B T2BT2AENCNCNONOZ1+Z1-S1-S1+ Z2+ Z2- S2-S2+ Z3+ Z3- S3-S3+ Z4-Z4+ S4+ S4- Z5+ Z5- S5-S5+ Z6+ Z6- S6-S6+ Z7+ Z7- S7-S7+ Z8-Z8+ S8+ S8- CC1 CC2 24+ 0CFT CFR R+ R-
POWER1 POWER 2
FS2 QB
3.15A
3.15A
3.15A
3.15A
3.15A
FS3
750mA
750mA
750mA
750mA
FS11 QB - UL Rated
500mA
500mA
500mA
500mA
FS5
750mA
750mA
FS7
750mA
FS9
750mA
FS4
750mA
750mA
750mA
750mA
FS6
750mA
750mA
FS8
750mA
FS10
750mA
Fuse
1-Zone panel
2-Zone panel
4-Zone panel
8- Zone panel
Repeat panel
SECTOR 1
SECTOR 2
SECTOR 3
SECTOR 4
SECTOR 5
SECTOR 6
SECTOR 7
SECTOR 8BATTERIES
24V
18
All other fuses, ie FS1, FS2 and FS11
are 20mm x 5mm diameter
QB - Quick Blow AS - Anti-Surge
Fuses
T1A
T1B
E
CFR
24+
CFT
0
CC1
CC2
R+
R-
NC
NC
NO
NO
Zn+
Zn-
To Zone and Sounder
Circuits, where `n' signifies
circuit number 1 to 8
Sn-
Sn+
Auxiliary contacts
1A at 24Vdc resistive
To transformer
Mains input
supply
Software
version
label
P1
P3 to P6
P7
Class change, connect to XEN-FFR
Common fault,
Common Fire
Repeat panel
Panel
P8
EEPROM
Protection
fitted across
pins 1 and 2
Power
Shift
Display
NE L
The terminal blocks
are not fitted on the
shaded
Repeat panel.
FS1 (MAINS) AS
3.15A
3.15A
3.15A
3.15A
3.15A
All sector outputs have resettable 0.75A fuses which do not
need replacing. The individual outputs will recover after
removing the fault. The recovery time is 30 seconds minimum
and it is recommended that the sectors be switched off (Silence Alarms).
Delay
Figure 12 Panel terminals and fuses