EasyManuals Logo
Home>Honeywell>Measuring Instruments>Class 320 Meter

Honeywell Class 320 Meter User Manual

Honeywell Class 320 Meter
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #34 background imageLoading...
Page #34 background image
CLASS 320 METER
62-0397-02 34
9.0 LITHIUM BATTERY REPLACEMENT
The Class 320 meter has a lithium coin cell battery, which is used to retain the
contents of SRAM and the RTC during power outages. The battery’s life expectancy is
greater than 5 years.
Table 1. Battery specifications at 25 degrees Celsius.
WARNING
Replace battery with Panasonic part number CR2032 only. Use of another
battery may present a risk of fire or explosion. See owner’s manual for safety
instructions.
The battery cell is mounted in a coin cell holder on the upper right side of the main
power board. The internal unit firmware will set a flag to indicate the low battery
condition. When the unit data is next downloaded, the monitoring facility will be alerted
of the low battery condition and will schedule a service call.
Fig. 23. Lithium Battery Cell.
CAUTION
Battery may explode if mistreated. Do Not recharge, disassemble, or dispose
of in fire.
Nominal Working Voltage 3 Vdc Output
Nominal Current Capacity 225 mAHr
Cell Chemical Manganese Dioxide Lithium
Operating Temperature Range -30 to +60 Degrees Celsius
Manufacturer Panasonic
Manufacturers Part Number CR2032
M33197
BATTERY
+