4.4 Saving or Cancelling Modifications
DO OT FORGET TO SAVE YOUR COFIGURATIO!!
Note that after saving a configuration, if all the panel LEDs light in succession, one or more
parameters has been set with an incorrect value. The installation cannot be completed until
this has been corrected. Please restart programming.
4.5 Testing the Installation
PANEL STATUS
--------------------
BATTERY KO
TAMPER OK
MAINS KO
QUIT (
)
DEVICE STATUS
--------------------
BATTERY OK
TAMPER KO
SUPERV KO
OTHER OK
QUIT (
)
TRANSM. STATUS
---------------------
GSM KO
GPRS KO
PSTN OK
ETHERNET OK
GSM LEVEL 0
DONE (OK/
)
Checking faults on the panel and peripherals:
Checking the network connection status:
1-REGISTER
2-DEVICES
3-PARAMETERS
4-DATE & TIME
5-SYSTEM DIAG.
6-TRANSM.STATUS
7-RADIO SCAN
8-ABORT
9-SAVE+QUIT
1-REGISTER
2-DEVICES
3-PARAMETERS
4-DATE & TIME
5-SYSTEM DIAG.
6-TRANSM.STATUS
7-RADIO SCAN
8-ABORT
9-SAVE+QUIT
PANEL VERSION
--------------------
CUSTOMER ..X.......
Ref tech S/W ver ..
SN: ………………...
VAT: 7.56 …………..
QUIT (
)
The panel version is indicated for the default settings, designation/customer, manufacturing reference,
software version, serial number and VAT data structure.
“OTHER” in the Device Status screen notifies you of specific faults on a device, e.g. a dirty chamber in
a smoke sensor.
13
EnglishProgramming