EasyManuals Logo
Home>Honeywell>Network Hardware>VARIODYN D1

Honeywell VARIODYN D1 User Manual

Honeywell VARIODYN D1
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
Installation Instruction VARIODYN
®
D1 System
14 FB 798663.GB0 / 05.19
3.4.1 System cables (overview)
The following system cables are required for directly connecting the devices in the installation cabinet:
Name Part No.
Patch cable CAT5, 1 m, yellow, (ETH) VARIODYN
®
D1 583486A
Patch cable CAT5, 2 m, yellow, (ETH) VARIODYN
®
D1 583487A
Patch cable CAT5, 3 m, yellow, (ETH) VARIODYN
®
D1 583488A
Patch cable CAT5, 1 m, blue, (DAL) VARIODYN
®
D1 583481A
Patch cable CAT5, 2 m, blue, (DAL) VARIODYN
®
D1 583482A
Patch cable CAT5, 3 m, blue, (DAL) VARIODYN
®
D1 583483A
Patch cable CAT5, 1 m, grey, (DAL) VARIODYN
®
D1 583466A
Patch cable CAT5, 2 m, grey, (DAL) VARIODYN
®
D1 583467A
Patch cable CAT5, 3 m, grey, (DAL) VARIODYN
®
D1 583468A
Signal cable 12 for UIM
®
D1 for connecting control contacts.
Ex works cabling of 12 control contacts of the UIM to the rear cabinet wall; up to 4 cables are
required per UIM
583401.21
Cable for rear cabinet wall and/or relay contacts DOM4-8 for loudspeaker connection.
Ex works cabling of the loudspeaker/speaker (SPK) outputs of the DOM4-8 to the rear
cabinet wall; 1 cable required per DOM4-8
583451.21
Cable for rear cabinet wall DOM4-24 for loudspeaker connection.
Ex works cabling of the loudspeaker/speaker (SPK) outputs of the DOM4-24 to the rear
cabinet wall; up to 4 cables are required per DOM4-24
583452.21
Input cable DOM XV VARIODYN
®
D1
Ex works cabling of DOM (1) to final amplifier (1), 2 channels (audio frequency (AF), control)
583471.21
Output cable XV DOM VARIODYN
®
D1
Ex works cabling from final amplifier (1), 2 channels (max. 100 V) to DOM (1)
583476.21
Backup cable RC 22 VARIODYN
®
D1
Ex works cabling from 2 backup channels to the backup channel of the DOM
583422.21
Input cable DOM RJ45 - XVRJ45
Prefabricated cabling from DOM (2) to final amplifiers (2), 2 channels (AF, control)
583491A
Output cable 2XV - DOM VARIODYN
®
D1
Prefabricated cabling from 2 final amplifiers (2), 4 channels (max. 100 V) to DOM (2)
583477.21
Input cable DOM - XVRJ45
Prefabricated cabling from DOM (1) to final amplifiers (2), 2 channels (AF, control)
583472.21
Input cable DOMRJ45 - XV
Prefabricated cabling from DOM (2) to final amplifiers (1), 2 channels (AF, control)
583473.21
Various types of cabling are required depending on the hardware version (1) or (2) of the DOM and
the power amplifier.
(1): 583361.03 (DOM4-8); 583362.03 (DOM4-24)
(2): 583361.21 (DOM4-8); 583362.21 (DOM4-24)
580221.41 (2XH250); 580222.41 (2XH500); 580231.41 (2XD250), 580232.41 (2XD400)