NOTE:
If the problem persists, contact the HP technical support for help.
Fan failure
You can look at the system status LED and the seven-segment LED of an 3600 v2 switch to identify a fan
failure. If both LEDs are behaving as described in Table 7, a fan failure occurs.
Table 7 LED behaviors for fan failure
LED Mar
System status LED PWR Steady red
Seven-segment LED Unit
The LED displays F for fan failure.
The 3600 v2 Switch Series uses fixed fans. If a fixed fan failure occurs, you cannot solve the problem
yourself. Contact your sales agent or service engineer.
NOTE:
To ensure the normal operation of the switch, contact the local sales a
ineer as soon as
possible when a fixed fan failure occurs.
Configuration terminal problems
If the configuration environment setup is correct, the configuration terminal displays booting information
when the switch is powered on. If the setup is incorrect, the configuration terminal would display nothing
or garbled text.
No terminal display
If the configuration terminal displays nothing when the switch is powered on, check that:
• The power supply is normal.
• The console cable is properly connected.
• The console cable has no problem and the terminal settings are correct.
Garbled terminal display
If terminal display is garbled, check that the following settings are configured for the terminal, for
example, HyperTerminal:
• Baud rate—9,600
• Data bits—8
• Parity—none
• Stop bits—1
• Flow control—none
39