5. Re-tighten the captive retainer thumbscrews
6. Replace the I/O cable(s).
1 2
SAS IN from RAID controller in server or from previous enclosure1
SAS OUT to next enclosure2
7. Read the LEDs to confirm the unit is operating. See Storage enclosure LEDs (page 26).
Removing and replacing a power supply module
NOTE: If one of the PSUs is removed and re-inserted, but the power cord is not reattached,
the hardware report will show the failed AC Supply & a TempSensor Failure.
1. Remove the power cable from the power supply to be replaced.
2. Press the latch (1) and slide the power supply module out of the enclosure (2).
Removing and replacing a power supply module 57