EasyManuals Logo
Home>HP>Monitor>L1502

HP L1502 User Manual

HP L1502
69 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
8
HP L1502 LCD
Go to cover page
Factory mode
Front control panel
Fig.1
Basic and simple instruction on the control keys.
When you press the button on the front control of your monitor, the On-
Screen Display (OSD) Main Controlswindowwill pop upandyou can
then start making adjustments to your monitor's various features.
Access Factory Mode
How to Get into Factory Mode Menu
Step.1Turn off monitor.
Step 2 :
[Push " " & " + " buttons at the same time and hold it ]+
[Press power ""button untill comes out "Windows screen"
]=>then releaseallbuttons.
Step 3
Press " " button,bring up Factory mode indication as
showninFig2.
Fig.2
VAL:
READ
SUB-BRI : Brightness value range(Min Max).
Fixvalue for continue mode requirement.
SUB-CON : Contrastvalue range(Min Mid Max)
SRGB : is equal to 6500K
Gain-m :Minimum valueofUser Gain
Gain-M : Maximum valueofUser Gain
AUTO-SUB: TodoAuto color function when
push “Up”key in white pattern
IDX : Limit current of inv
erter (FixvalueLG: 7, CPT: 28)
Panel Type:Ifset this to 1111, 2222 then system will
force panel type to LG,CPT
SCALER : Read/Write scaler register

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP L1502 and is the answer not in the manual?

HP L1502 Specifications

General IconGeneral
BrandHP
ModelL1502
CategoryMonitor
LanguageEnglish

Related product manuals