HP Array Configuration Utility 59
Identifying devices
You can enter a command that causes the LEDs on target devices to flash, enabling you to identify the
devices. After an hour, the LEDs stop flashing. You can also stop LED flashing by entering the off command.
Syntax:
<target> modify led=on|off
Example commands:
=> ctrl ch="Lab 4" modify led=on
=> ctrl ch="Lab 4" array A modify led=off
Deleting target devices
Syntax:
<target> delete [forced]
where <target> can be a controller, array, or logical drive. Except in the case of controllers, you can
delete several devices simultaneously if they are of similar type by using the all keyword.
Because deleting a target device can result in data loss, the screen displays a warning prompt unless you
include the forced parameter.
Example commands:
=> ctrl ch="Lab 4" delete forced
=> ctrl slot=3 ld all delete
Generating a diagnostic report
HP provides several ways for administrators to generate diagnostic information, including all three ACU
formats and the standalone HP Array Diagnostics and SmartSSD Wear Gauge Utility.
In ACU CLI, the diag command outputs diagnostic information about a specified controller or all controllers
on the system. The ssdrpt option generates the SmartSSD Wear Gauge report.
Syntax:
<target> diag <file=filename> [ris=on|off] [ssdrpt=on|off] [xml=on|off]
[zip=on|off]
where the following is designated:
<target> is a controller or all controllers.
<file=filename> designates the target file in which the diagnostic information is saved.
[ris=on|off] determines whether RIS information is or is not included. The off value is provided for
backward compatibility and is ignored.
[ssdrpt=on|off] specifies to generate or not generate the Smart SSD Wear Gauge report. The
default is off.
[xml=on|off] outputs diagnostic information in formatted XML. The off value is provided for
backward compatibility and is ignored.
[zip=on|off] compresses the output to a zipped file. Default behavior is uncompressed. The off
value is provided for backward compatibility and is ignored.
Example commands:
ctrl all diag file=c:\allcontrollers.zip
ctrl slot=4 diag file=c:\ctrl_slot4.zip
ctrl ch="mybox" diag file=mybox.zip ssdrpt=on

Table of Contents

Other manuals for HP ProLiant DL360p

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant DL360p and is the answer not in the manual?

HP ProLiant DL360p Specifications

General IconGeneral
Max Processors2
Form Factor1U Rack
MemoryUp to 768GB DDR3
Memory Slots24
RAID SupportHP Smart Array P420i Controller
Network4 x 1Gb Ethernet ports
Power Supply460W, 750W
ManagementHP iLO (Integrated Lights-Out)
Storage8 SFF or 4 LFF

Related product manuals