EasyManuals Logo
Home>Huawei>Conference System>RRU5309

Huawei RRU5309 User Manual

Huawei RRU5309
125 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #100 background imageLoading...
Page #100 background image
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Next topic >
7.2.2.8.5 Installing an RRU PGND Cable
This section describes the procedure for installing an RRU PGND cable.
Context
The cross-sectional area of an RRU PGND cable is 16 mm
2
(0.025 in.
2
). The cable has an M6 OT
terminal at one end and an M8 terminal at the other end.
DANGER:
Install RRU PGND cables by strictly following the following operations. Otherwise, damage to the
RRU or personal injury may occur.
Procedure
1. According to the actual cable route, cut the PGND cable into a proper length to prepare an RRU
PGND cable. Then, add an OT terminal at each end of the cable according to the instructions in
Assembling the OT Terminal and the Power Cable.
2. Install the RRU PGND cable.
Connect the M6 OT terminal at one end of the PGND cable to the ground terminal at the RRU
bottom and the M8 OT terminal at the other end to the external ground bar, as shown in Figure 1.
Figure 1 Installing an RRU PGND cable
NOTE:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei RRU5309 and is the answer not in the manual?

Huawei RRU5309 Specifications

General IconGeneral
BrandHuawei
ModelRRU5309
CategoryConference System
LanguageEnglish

Related product manuals