Figure 4 Waterproofing the connector on the AISG multi-wire cable
(1) Waterproof tape
(2) PVC insulation tape
6. Route the cables according to the instructions in Cabling Requirements.
7. Label the installed cables according to the instructions in Attaching an L-Shaped Label.
Parent Topic: Installing RRU Cables
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >
7.2.2.8.8 Opening the Cover Plate of an RRU
Cabling Cavity
This section describes the procedure for opening the cover plate of an RRU cabling cavity.
Procedure
1. Wear ESD gloves.
NOTICE:
Take proper ESD protection measures, for example, wear ESD gloves, to prevent electrostatic
damage to the boards, modules, or electronic components.