Troubleshooting
Display Possible Cause Solutions
DISPLAY SHOWS “ERR”
WITH NUMBER
Short in eld wiring or bad solenoid. Check eld wiring and valve solenoid. Press any button to clear
ERR message.
DISPLAY SHOWS P “ERR” Short in P/MV wiring or solenoid. Check wiring and solenoid at P/MV. Check specications for Pump
Start Relay.
DISPLAY SHOWS SP
“ERR
SmartPort
®
error. Electrical noise is
present near connection to remote
or other SmartPort device.
Move connections away from sources of electrical noise. Verify that
controller has been wired correctly.
Wire from SmartPort Attach wire to:
Red 24 VAC (AC terminal 1)
White 24 VAC (AC terminal 2)
Blue Remote terminal (REM)
DISPLAY SHOWS
WATERING BUT
NO WATERING IS
OCCURRING
Problem in eld wiring. Problem
with solenoids. No water pressure
to system.
Check eld wiring (voltmeter). Check valve solenoid(s). Verify water
source to open.
FROZEN OR GARBLED
DISPLAY
Power surge occurred. Reset controller.
RAIN SENSOR DOES NOT
STOP IRRIGATION
Jumper wire is not removed. Sensor
switch in BYPASS position.
Remove jumper wire on SEN terminals. Set sensor switch to
Active position.
CONTROLLER SEEMS TO
WATER CONTINUOUSLY
Too many START TIMES. One Start Time operates all stations in a program. Remove
unnecessary Start Times.

Other manuals for Hunter X-CORE XC-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hunter X-CORE XC-2 and is the answer not in the manual?

Hunter X-CORE XC-2 Specifications

General IconGeneral
BrandHunter
ModelX-CORE XC-2
CategoryController
LanguageEnglish

Related product manuals