Maintenance
Restoring from service position
1 Grip the front edge of the unit and loosen the lock, fold
down and slide in the unit.
2 Replace the cutting height stay and the belt.
3 Tension the belt with the belt adjuster.
4 Fit the front cover.
Checking the blades
To achieve the best mowing results it is important that the
blades are undamaged and well-sharpened.
Check that the blades’ attachment screws are tight.
The blades should be balanced after sharpening.
Damaged blades should be replaced when hitting obstacles
that result in a breakdown. Let the servicing dealer judge
whether the blade can be repaired/ground or must be
discarded.
Removing the BioClip plug
To change a Combi unit from BioClip function to cutting unit
with rear ejection, remove the BioClip plug located under the
unit with three screws.
1 Put the unit in the service position, see Placing in the
service position.
2 Remove the three screws holding the BioClip plug, and
remove the plug.
3 Tip: Fit three full-thread screws M8x15 mm in the screw
holes to protect the threads.
4 Replace the unit in normal position.
Fit the BioClip plug in the reverse order.
IMPORTANT INFORMATION Replacing or sharpening the
blades should be conducted by an authorised service
workshop.