EasyManuals Logo
Home>IBM>Switch>2498B24 - System Storage SAN24B-4 Switch

IBM 2498B24 - System Storage SAN24B-4 Switch User Manual

IBM 2498B24 - System Storage SAN24B-4 Switch
77 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
Ethernet LED patterns
Each Ethernet port has two LEDs, which are described in Table 7
Table 7. Ethernet LED patterns
LED name LED color Status of hardware
Recommended
action
Ethernet speed LED
(right)
No light Port speed is 10
Mb/sec.
No action is required.
Steady green Port speed is 100
Mb/sec.
No action is required.
Ethernet link status
LED (left)
No light No link detected Verify the Ethernet
cable is connected
correctly.
Blinking amber There is link activity
(traffic).
No action is required.
Solid Amber There is a link. No action is required.
POST and boot specifications
When the switch is turned on or rebooted, the switch performs POST. Total boot
time with POST is up to 3 minutes. POST can be omitted after subsequent reboots
by using the fastboot command or entering the diagDisablePost command to
persistently disable POST.
For more information about these commands, refer to the Fabric OS Command
Reference Manual.
POST
The success or failure results of the diagnostic tests that run during POST can be
monitored through the error log or the command line interface.
POST includes the following steps:
1. Preliminary POST diagnostics are run.
2. Operating system is initialized.
3. Hardware is initialized.
4. Diagnostic tests are run on several functions, including circuitry, port
functionality, memory, statistics counters, and serialization.
Boot
In addition to POST, boot includes the following steps after POST is complete:
1. Universal port configuration is performed.
2. Links are initialized.
3. Fabric is analyzed, and if any ports are connected to other switches, the switch
participates in a fabric configuration.
4. Switch obtains a domain ID and assigns port addresses.
5. Unicast routing tables are constructed.
6. Normal port operation is enabled.
Chapter 3. Operating the switch 25
|
|
|
|
|
|
|
||

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM 2498B24 - System Storage SAN24B-4 Switch and is the answer not in the manual?

IBM 2498B24 - System Storage SAN24B-4 Switch Specifications

General IconGeneral
BrandIBM
Model2498B24 - System Storage SAN24B-4 Switch
CategorySwitch
LanguageEnglish

Related product manuals