configuring the printer
10 Multi–Platform Interface Feature Operation Guide
PRINTER CONTROL
SHUTTLE TIMEOUT ........ 20 SECONDS
PARALLEL INTERFACE
INTERFACE TYPE ........ PC PARALLEL
PC PARALLEL
DATA BIT 8 ......... ENABLE
DATA POLARITY ........ STANDARD
STROBE POLARITY ....... STANDARD
RESPONSE POLARITY ...... STANDARD
BUSY ON STROBE ....... ENABLE
LATCH DATA ON ........ TRAILING EDGE
PRIME SIGNAL ........ DISABLE
TOF ACTION AT PRIME SIGNAL . NO ACTION
Table 3 Printer Configuration
note
In Table 3 , only the values for Shuttle
Timeout, Latch Data On, and Prime Signal
need to be changed. For all other
configuration items, the default values can
be used. If the values shown in bold in Table
3 are not set as shown, erratic operation of
the printer might occur.