30
QUICK: F1
F1
Quick
F2
Genrl
F3
Disp
F4
Kybd
F5
Keys
F6
Ports
F7
Host
F8
Print
F9
Emul
F10
Tabs
F11
AnsBk
F12
Prog
Print
Exec
ParametersParameters
Emulation=IBM 3151 EIA Baud Rate=9600 EIA Data Format=8/1/N
Enhance=On Aux Baud Rate=9600 Aux Data Format=8/1/N
Comm Mode=Full Duplex Language=U.S. Sessions=One
Host/Printer=EIA/Para
ChoicesChoices
ADDS VP Wyse 60 Wyse 50+ PC Term VT300/7 VT300/8 VT200/7
VT200/8 VT100 SCO Console IBM 3151 TVI 925 AT386
SelectSelect
↑ → ↓ ← : Parameter
Enter/S-Enter : Next/Prev Choice Exit : Setup Key
Emulation: [ADDS VP, Wyse 60, Wyse 50+, PC Term, VT300/8, VT300/7, VT200/8, VT200/7, VT100,
IBM 3151, SCO Console, AT386, TVI 925]
Select the “personality” of the terminal (the way in which it responds to
commands). If you are using PC-Term emulation, refer to the Local Leadin
selection in the Keys: F5 section for access to local “hot keys.”
All associated defaults are loaded when the emulation is
changed. Default choices are in bold. Some defaults may
vary depending on the selected emulation.
Comm Mode: [Full Duplex, Half Duplex, Full Block, Half Block]
Select the method of communication to match the host computer.
EIA Baud Rate: [110, 150, 300, 600, 1200, 1800, 2000, 2400, 4800, 9600,
19200, 38400, 57600, 76800, 115200, 134400]
Select the number of bits communicated per second to match the speed at
which the primary host or printer expects to communicate.
Aux Baud Rate: [110, 134.5, 150, 300, 600, 1200, 1800, 2000, 2400, 4800,
9600, 19200, 38400]
The speed at which the secondary host or printer expects to communicate.