Failing Item Description Document Description
CVTCARD HSL (SI) I/O Adapter for FC 5076 SPD migrated
tower
Problem Analysis; Symbolic FRU Isolation
DEVTERM Terminating plug Problem Analysis; Symbolic FRU Isolation
DISKDRV Disk Drive and Logic Card Problem Analysis; Symbolic FRU Isolation
DISKTRY Disk unit tray Problem Analysis; Symbolic FRU Isolation
DRVSWCH Drive address switch Problem Analysis; Symbolic FRU Isolation
GG3COMM Communications failure
GG3FFDC LIC program failed and data was captured
GG3PL01 System performance problem
GG3PL02 Network performance problem
GG3PL03 Switched link activation failure message not
answered
GG3PL04 Transmission groups in the network must be
activated
GG3PL05 Class-of-service specified does not provide a
route
GG3PL06 COS acceptable TGs and nodes do not exist for
the route
LBUSADP SPD local bus adapter, where optical daughters
plug
Problem Analysis; Symbolic FRU Isolation
LOC_SYS Local HSL Opticonnect system or partition. Local HSL OptiConnect system
LPARCFG LPARCFG LPAR configuration - processors,
memory or ld src
Problem Analysis; Symbolic FRU Isolation
LPARSUP LPARSUP LPAR complex problem, call next
level of support.
Problem Analysis; Symbolic FRU Isolation
MABRCFG Multi-adapter bridge configuration error or
change
Problem Analysis; Symbolic FRU Isolation
MASBUS Multi-adapter bridge secondary bus or card slot Problem Analysis; Symbolic FRU Isolation
MA_BRDG Multi-adapter bridge high level symbolic Problem Analysis; Symbolic FRU Isolation
OPTDRIV Optical Disk Drive Problem Analysis; Symbolic FRU Isolation
OPTLCBL Optical Library drive cabling Problem Analysis; Symbolic FRU Isolation
OPTLDRV Optical Library optical drive Problem Analysis; Symbolic FRU Isolation
OPT_CLN Fiber optic cleaning kit Fiber optic cleaning kit
PIOCARD PCI nodes adapter card, IOP or IOA Problem Analysis; Symbolic FRU Isolation
PPCIMIN Primary PCI bus in 5075 I/O tower Problem Analysis; Symbolic FRU Isolation
PPCISYS Primary PCI bus in a system unit Problem Analysis; Symbolic FRU Isolation
PPCITWR Primary PCI bus in a 5074 I/O tower Problem Analysis; Symbolic FRU Isolation
PRI_PCI Primary system PCI bus to a MaB, high level
symbolic
Problem Analysis; Symbolic FRU Isolation
REM_NIC A remote NIC in a cluster.
REM_SYS HSL opticonnect remote system or partition. Remote HSL OptiConnect system
SIADPCD High Speed Link (SI) I/O adapter card in FC
5074 I/O tower
Problem Analysis; Symbolic FRU Isolation
SICNTRL HSL (SI) controller, high level symbolic Problem Analysis; Symbolic FRU Isolation
B6xx (including A6xx)
System Reference Codes 297

Table of Contents

Other manuals for IBM iSeries 820

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 820 and is the answer not in the manual?

IBM iSeries 820 Specifications

General IconGeneral
BrandIBM
ModeliSeries 820
CategoryServer
LanguageEnglish

Related product manuals