EasyManuals Logo
Home>IBM>Server>Power 720

IBM Power 720 User Manual

IBM Power 720
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #104 background imageLoading...
Page #104 background image
90 IBM Power 720 and 740 Technical Overview and Introduction
probably be slowed until the controller pairing is established again. This ultra-dense SSD
option is similar to the Ultra Drawer (FC 5888), which remains available to B and C-models of
the Power 720, and Power 740.
Figure 2-31 shows the picture of the EXP30 drawer.
Figure 2-31 Front view of the EXP30 drawer
Each controller is connected to a GX++ 2-port PCIe2 x8 adapter (FC EJ03 CCIN 2C1E) in a
Power 720 and Power 740 server through a PCIe x8 cable. Usually both controllers are
attached to one server, but each controller can be assigned to a separate server, or a logical
partition.
Table 2-27 lists the RAID levels for the AIX, IBM i, Linux operating system, which are
supported by the controller.
Table 2-27 Supported RAID levels
The EXP30 Ultra SSD I/O drawer (FC EDR1) delivers up to 480,000 IOPS (read only), up to
410,000 IOPS (60% read and 40% write), or up to 325,000 IOPS (100% write) and has up to
30% performance improvement over the previous version of the EXP30 (FC 5888).
Reminder: The previous EXP30 drawer (FC 5888) is not supported on the D-models of
the Power 720 and Power 740 servers.
RAID level Operating system
RAID 0 AIX, Linux
RAID 1
a
a. Provided by the operating system (LVM)
AIX, IBM i, Linux
RAID 5 AIX, IBM i, Linux
RAID 6 AIX, IBM i, Linux
RAID 10 AIX, Linux

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Power 720 and is the answer not in the manual?

IBM Power 720 Specifications

General IconGeneral
BrandIBM
ModelPower 720
CategoryServer
LanguageEnglish

Related product manuals