Page #71 background imageLoading...
Page #71 background image
Figure 54. Loosening the NVMe drive backplane screws
8. Pull the NVMe drive backplane (B) away from the chassis that uses the thumbscrews, then lift the
NVMe drive backplane from the chassis. See Figure 54 on page 57.
9. If the removed part is used again, place the part on an electrostatic discharge (ESD) mat.
Replacing the NVMe drive backplane in the 9009-22G system
To replace a NVMe drive backplane in the system, complete the steps in this procedure.
Procedure
1. Ensure that you have the electrostatic discharge (ESD) wrist strap on and that the ESD clip is plugged
into a ground jack or connected to an unpainted metal surface. If not, do so now.
2. The chassis has four alignment pins (B) to secure the NVMe drive backplane (A). Insert the NVMe drive
backplane as shown in the following gure. Ensure that the alignment pins t through the holes in the
NVMe drive backplane.
Drive backplanes for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, or 9223-22H