ServeRAID M5014/M5015 SAS/SATA Controller Descriptions 3-3
JT6 x4 SAS Ports 3–0 Mini SAS 4i
connector
Connects the cables from the
controller to SAS drives or SATA II
drives, or a SAS expander.
JT7 x4 SAS Ports 7–4 Mini SAS 4i
connector
Connects the cables from the
controller to SAS drives, SATA II
drives, or a SAS expander.
JT8 ServeRAID M5000
Series Advanced
Feature Key header
2-pin
shielded
header
Enables support for RAID 6
configurations and self-encrypting
disks (SED).
JT9 Set Factory Defaults
connector
2-pin
connector
Returns the board settings to the
defaults set in the factory.
JT10 LSI Test header 2-pin
connector
Reserved for IBM use.
JT11 IPMI-style SMBus
(System Manage-
ment)/I
2
C header
3-pin
shielded
header
Provides enclosure management
support.
JT12 Individual Drive
Fault LED header for
Eight Phys (0-7)
16-pin
connector
Indicates drive faults. There is one
LED per port. When lit, each LED
indicates the corresponding drive
has failed or is in the
Unconfigured-Bad state. Refer to
the ServeRAID-M SAS Software
User’s Guide for more information.
The LEDs function in a direct-
attach configuration (there are no
SAS expanders). Direct attach is
defined as a maximum of one drive
connected directly to each port.
This header is used for controllers
with internal SAS ports.
JT13 Universal
Asynchronous
Receiver/Transmitter
(UART) debugging
4-pin
connector
Reserved for IBM use.
Table 3.1 ServeRAID M5014 and ServeRAID M5015 Controllers
Connectors (Cont.)
Connector Description Type Comments