7-4
RECEIVER
ADJUSTMENT
ADJUSTMENT
2nd
LO
(D/A)
ADJUSTMENT
MEASUREMENT
POINT
|
VALUE
UNIT
LOCATION
UNIT
|
ADJUST
MAIN
|
Connect
the
MAIN
|R38,
R153
frequency
counter
to
R51
and
R52
(GND).
ADJUSTMENT
CONDITIONS
Preset
to
center.
35.3000
MHz
Connect
the
RF
Maximum
level
voltmeter
to
R47
and
|
(More
than
300
mVrms)
e
Displayed
frequency:
144.100
MHz
(FRG
version)
120.100
MHz
(All
other
versions)
:
FM
R38
L7,
(8
R9
(GND).
е
Displayed
frequency:
144.105
MHz
(FRG
version)
120.105
MHz
(All
other
versions)
*
Mode
:
FM
*
Remove
RF
voltmeter.
Connect
the
35.2950
MHz
R153
frequency
counter
to
R51
and
R52
(GND).
35.3000
MHz
R38
|
|
e
Displayed
frequency:
144.100
MHz
(FRG
version)
120.100
MHz
(All
other
versions)
*
Mode
:FM
Repeat
steps
4
and
5
several
times.
MAIN
|
Connect
the
digital
DC
voltmeter
to
R88.
e
Displayed
frequency:
144.100
MHz
(FRG
version)
120.100
MHz
(All
other
versions)
e
Mode
:
WFM
e
[PRE/
ATT]
switch
:
OFF
e
Set
the
signal
generator;
Level
:
3.2
uV*
(一
97
dBm)
Modulation:
1
kHz
Deviation
:
50
kHz
*
This
output
level
of
the
standard
signal
generator
(SSG)
is
indicated
as
SSG's
open
circuit.