51
11
SET MODES
■ INITIAL SET MODE
The
INITIAL SET MODE
is accessed at power on and allows you
to set seldom-changed settings. In this way, you can “cus-
tomize” transceiver operations to suit your preference and op-
erating style.
DD
Entering INITIAL SET MODE
q While pushing and holding [
YY
] and [
ZZ
], turn power ON.
w Push [
YY
] or [
ZZ
] to select the desired item.
e Rotate [VOL] to select the condition or value.
•To exit
INITIAL SET MODE
, push [✱
ENT
] (or [CLR]).
DD
Key-touch beep
Turns key-touch beep emission ON (Beep level 1 to 3) or
OFF. (default: 3)
NOTE: The pocket beep level (Beep level 1 to 3 or OFF)
also changes as this setting.
DD
Time-out timer
To prevent accidental prolonged transmission, etc., the trans-
ceiver has a time-out timer. This function cuts a transmission
OFF after 1–30 min. of continuous transmission. This timer
can be cancelled.
• tOt.OF : The time-out timer is turned OFF.
• tOt. 1–30: The transmission is cut OFF after the set period
elapses. (default: 3)
• BE CAREFUL! The transceiver will become hot when
this time-out timer function is turned OFF and transmis-
sion is made for long periods.
• NOTE: When the battery pack (BP-227) becomes hot
from continuous transmittion, etc., the battery’s protection
circuit may activate to protect the battery itself and then
shut off the transceiver power until it has cooled down.