FLUEING OPTIONS
LOGIC COMBI ESP, HEAT & SYSTEM.
50
ROOF FLUE SYSTEM.
ROOF FLUE SYSTEM
WITH 2 X 45° ELBOW.
NOTE:
* 152258: Weather collar universal 100 dia (suits any roof pitch)
152259: Weather collar flat roof 100 dia
NOTE:
* 152258: Weather collar universal 100 dia (suits any roof pitch)
152259: Weather collar flat roof 100 dia
FLUE IDEAL
PART NO.
MAXIMUM
STRAIGHT
FLUE LENGTH
(MM)
Roof flue kit (with vertical connector)
+ Weather collar
211039
152258/152259*
1325
Roof flue kit
+ 7 x (max) Flue extension 1m (pack D)
+ Weather collar
211039
7 x 203129
152258/152259* 7500
FLUE IDEAL
PART NO.
MAXIMUM
STRAIGHT
FLUE LENGTH
(MM)
Roof flue kit (with vertical connector)
+ 6 x (max) Flue extension 1m (pack D)
+ 2 x Flue elbow 45° kit (60/100)
+ Weather collar
211039
6 x 203129
203131
152258/152259*
6300