SERVICING
Independent + Combi - Installation and Servicing
45
IGNITION ELECTRODE REPLACEMENT
1. Refer to Frame 40.
2. Remove the burner. Refer to Frame 43.
3. Unplug the ignition lead from the electrode.
4. Remove the earth lead from the ignition
electrode.
5. Remove the 2 screws holding the ignition
electrode to the combustion chamber.
6. Remove the electrode.
7. Fit the new ignition electrode, using the new
gasket supplied. Check dimensions as shown.
8. Reassemble in reverse order.
9. Check the operation of the boiler. Refer to
Frames 29 & 30.
44
RETURN THERMISTOR RENEWAL
1. Refer to Frame 40.
2. Unclip the return thermistor from the return pipe and withdraw it from the
boiler.
3. Disconnect the electrical lead from the thermistor.
4. Reconnect the electrical lead to the new thermistor and reassemble in
reverse order, ensuring that the thermistor is securely tted to the pipe on the
thermistor locator tab as shown.
5. Check the operation of the boiler. Refer to Frames 29 & 30.
2
Ignition Electrode
3mm
Straight edge
Spark Gap
3.5mm
Thermistor Locator Tab
(with thermistor tted)
5
SERVICING

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEAL Independent + Combi C24 and is the answer not in the manual?

IDEAL Independent + Combi C24 Specifications

General IconGeneral
BrandIDEAL
ModelIndependent + Combi C24
CategoryBoiler
LanguageEnglish

Related product manuals