INSTALLATION
Independent + Combi - Installation and Servicing
3G9988
“A- See Diagram in
Frame 1
Extended centre line
155
(200)
3G9495
X
Section
through wall
Note. Check all of the hole
positions before drilling.
Side flue only
5" diameter hole
Rear flue only
5" diameter hole
The wall mounting template is located on the internal protective
packaging. The template shows the position of the xing and rear
ue centre holes for a standard installation
Care MUST be taken to ensure the correct holes are drilled.
1. Tape template into the required position, ensuring its squareness
by hanging a plumbline as shown.
2. If tting a side ue, extend the ue centreline onto the side by
155mm on a standard wall x or 200mm if using a stand-off
bracket.
3. Mark the following on to the wall:
a The selected group of wall mounting screw holes.
b. The centre position of the ue duct. Marking both the centre
and the circumference of the ue duct.
4. Remove the template plate from the wall.
9
WALL MOUNTING TEMPLATE
10
PREPARING THE WALL
IMPORTANT.
Ensure that, during the cutting operation, masonry falling
outside of the building does not cause damage or personal
injury.
1. Cut the ue hole (preferably with a 5” core boring tool),
ensuring that the hole is square to the wall.
Both wall faces immediately around the cut hole should be
at.
2. Drill 2 mounting holes (marked from template) with a 7.5mm
/ 8mm masonry drill and insert the plastic plugs, provided,
for the wall mounting plate.
3. Locate 2 No.14 x 50mm screws in the wall mounting plate
(one at each side, in any of the 3 holes provided at each
side) and screw home. Ensure mounting bracket is level.
12
MOUNTING THE BOILER
1. Ensure the plastic plugs are removed from both the CH
and DHW connections before mounting the boiler.
Note. boiler may contain residual water.
2. Lift the boiler onto the wall mounting plate (refer to the
Introduction section for safe handling advice), locating it
over the two tabs.
11
FITTING THE WALL MOUNTING PLATE
Screw the wall mounting plate to the wall using 2 wall plugs
(previously tted) with the 2 screws provided.
Choose one of the 2 sets of slots in left and right bank.
Ensuring that at least one of the screws is tted into a top slot
and the mounting bracket is level.
INSTALLATION

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEAL Independent + Combi C24 and is the answer not in the manual?

IDEAL Independent + Combi C24 Specifications

General IconGeneral
BrandIDEAL
ModelIndependent + Combi C24
CategoryBoiler
LanguageEnglish

Related product manuals