MODEL
SYMBOL UNITS 40 40P 60 60P
Condensing Boiler n/a n/a yes yes yes yes
Low Temperature Boiler n/a n/a no no no no
B1 Boiler n/a n/a no no no no
Cogeneration Space Heater n/a n/a no no no no
Equipped with a Supplementary Heater n/a n/a no no no no
Combination Heater n/a n/a no no no no
Nominal Heat Output for Space Heating
Full Load P
4 kW 40 40 60 60
Part Load P
1 kW 13 13 19.5 19.5
Auxiliary Electricity Consumption
Full Load el
max kW 0.135 0.135 0.092 0.092
Part Load el
min kW 0.03 0.03 0.026 0.026
Standby PSB kW 0.006 0.006 0.006 0.006
Seasonal Space Heating Energy Efciency
Full Load
ƞ
4
% 89.6 91.5 89.7 91.7
Part Load
ƞ
1
% 97.8 99.5 97.9 99.7
Standby Loss P
stby kW 0.08 0.08 0.11 0.11
Ignition Pign kW 0 0 0 0
Emissions NO
x mg/kWh 35 72 28 73
Annual Energy Consumption Q
HE GJ 123.9 122.6 185.8 181.9
Sound Power Level, Indoors LWA dB 53 53 52 52
ERP DATA