INSTALLATION
Ideal Logic + Combi - Installation and Servicing
9
FRONT PANEL REMOVAL
1. Loosen the 2 screws retaining the front panel.
2. Pull the two spring clips downwards to disengage.
3. Pull the front panel forward and upwards to remove.
Pack B Contents Telescopic
A Telescopic Flue Terminal
B Flue Turret
C Rubber Terminal Wall Seal
D Screw
E Sealing Tape
F Wall Seal (White)
D
C
A
E
F
B
1
2
Pack B Contents Non-Telescopic
A Flue Terminal
B Flue Turret
C Rubber Terminal Wall Seal
D Cutting Aid
E Wall Seal (White)
Note. This ue system incorporates a removable ue outlet nose that utilises a push t location system. This enables the
installation of deector, high level or balcony outlet ue kits without the removal of the whole ‘B’ pack terminal. The appliance
must not be operated without the desired outlet nose correctly tted in place.
Note. Location dimples must be aligned with terminal mounting frame.
A
D
B
CE
8
UNPACKING CONT’D
INSTALLATION