EasyManuals Logo

IDS X Series User Manual

IDS X Series
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background image
Section: 5
IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010
12
5. The LCD display reads „Zone Number + *‟.
6. Enter the [ZONE NUMBER] followed by the [*] key. Alternatively, you can use the [PANIC] and
[MED] keys to scroll through the zones.
7. [Y] next to the zone number indicates that the zone has been bypassed, whilst [N] indicates that
the zone has not been bypassed.
8. Press the [*] key to toggle between zones being on and off.
9. Repeat steps 6-8 to bypass/un-bypass other zones.
10. Press the [#] key to exit the bypass mode.
NOTE:
Panic zones cannot be bypassed.
6. Emergency Alarms
6.1 Fire Alarms
(Hold down the [F] key for two seconds until the keypad buzzer sounds)
If the [F] key is pressed until the keypad beeps (approximately 2 seconds) a FIRE ALARM
condition will be activated. The LCD display reads Alarm! alongside the relevant partition.
The FIRE ALARM CONDITION may also be triggered by a smoke detector connected to an
appropriately programmed zone.
The siren will sound on and off repeatedly, if programmed, and the FIRE REPORTING CODE will
be transmitted to the monitoring company.
To silence the siren enter a valid [USER CODE].
6.2 Panic Alarms
(Hold down the [P] key for two seconds until the keypad buzzer sounds)
If the [P] key is pressed until the keypad beeps (approximately 2 seconds) a PANIC ALARM
condition will be activated. The LCD display reads Alarm! alongside the relevant partition
number.
A PANIC ALARM may also be activated using any FIXED PANIC button or a REMOTE PANIC
button (if installed).
If the audible panic option has been selected, the siren will sound. A PANIC ALARM will be
transmitted to the monitoring company.
To silence the siren, enter a valid [USER CODE].
Press the [P] key only in an emergency situation that requires response by emergency
personnel.
6.3 Medical Alarms
(Hold down the [M] key for two seconds until the keypad buzzer sounds)
If the [M] key is pressed until the keypad beeps (approximately 2 seconds) a MEDICAL ALARM
condition will be activated.

Table of Contents

Other manuals for IDS X Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDS X Series and is the answer not in the manual?

IDS X Series Specifications

General IconGeneral
Key TypeTactile
BacklightYes
Operating Voltage12VDC
Weight150g
Operating Temperature-10°C to +55°C

Related product manuals