IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010
15
8.2 How to Enter the User Program Mode
1. Ensure that the panel is not armed.
2. Hold down the [*] key until the keypad buzzer sounds.
3. The LCD display reads Master Code + *. The factory default is [1234]. Should the MASTER
USER CODE be set to six digits it will be [123456] by default.
4. Enter the [MASTER USER CODE], followed by the [*] key. A valid entry will be confirmed by a
long beep. If an invalid MASTER USER CODE was entered, the keypad buzzer will give an error
beep (3 short beeps).
5. The first menu option „Option Menu‟, „Add User Code is displayed by default.
6. Select a programmable option from Table 1. One may use the [PANIC] or [MED] keys to scroll
through the menu options.
7. Confirm the entry by pressing the [*] key. A valid entry is confirmed by a long beep. An invalid
entry will be signalled by means of an error beep (3 short beeps). If an error beep occurs, press
the [#] key to clear all previous entries, and repeat steps 2 6.
EXAMPLE:
To add a new user code, enter User Program Mode by completing steps 2 - 4 as listed above. Menu
Option 0 will be displayed on the LCD screen by default. Press the [*] key to confirm your entry. Once
prompted to „Enter a User Code, input a [NEW USER CODE] followed by the [*] key. Once the user
code is programmed, enter the next code followed by [*]. To exit the program mode press the [#] key.
For a full list of options, refer to Table 1. Programming of these options is explained below.
8.3 Explanation of Programmable Options
8.3.1 Option 0 - Add a New User Code
[*] [MASTER CODE] [*] [0] [*] [NEW CODE] [*] [#]
1. Enter the User Program Mode as per steps 1 - 4 of section 8.2.
2. The LCD display reads „Option Menu‟, „Add User Code‟. As this is the programmable option you
require, press the [*] key.
3. The LCD display reads New Code + *.
4. Enter [NEW USER CODE] followed by the [*] key.
5. A valid entry is confirmed by a long beep. An invalid entry will be signalled by means of an error
beep (3 short beeps). If an error beep occurs, press the [#] key to clear all previous entries and
repeat steps 1-4.
6. Further codes can be added by repeating step 4 above. When a user code is added, it is stored
in the first available user slot.
7. Press the [#] key to exit the User Program Mode.
8.3.2 Option 1 - Edit a Selected User Code
[*] [MASTER CODE] [*] [1] [*] [OLD CODE] [*] [NEW CODE] [*] [#]
1. Enter the User Program Mode as per steps 1 - 4 of section 8.2.
2. The LCD display reads „Option Menu‟, „Add User Code‟.

Table of Contents

Other manuals for IDS X Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDS X Series and is the answer not in the manual?

IDS X Series Specifications

General IconGeneral
BrandIDS
ModelX Series
CategoryKeypad
LanguageEnglish

Related product manuals