EasyManuals Logo
Home>Inovance>Control Unit>GL20-4AD

Inovance GL20-4AD User Manual

Inovance GL20-4AD
22 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
10
Item Description
Current input accuracy (full temperature
range)
±0.2% (full range)
Current input limit ±30 mA (transient), ±24 mA (average)
Current input diagnosis Wire break detection supported only when
set to 4 to 20 mA
Isolation No isolation between the channels;
Isolation between the channels and the
power supply;
Isolation between the channels and the bus
Input action display N/A
Input derating N/A
Software specifications
Item Description
Independent channel enable
configuration
Supported
Diagnostic report configuration Supported
Diagnostic detection
configuration
Short circuit detection and wire break detection, not
supported by output range containing 0
Conversion mode configuration ±10 V, 0 to 10 V, ±5 V, 0 to 5 V, 1 to 5 V, ±20 mA, 0 to 20
mA, 4 to 20 mA
Filter parameter configuration The software filtering time can be configured through
the host controller, the setting range is 0‑65535
Overlimit detection
configuration
Supported
Peak hold configuration Supported
Digital output range
configuration
The default is consistent with that of GL10 (20000 to
20000) and supports ±32000
Sampling time 250 us for four channels

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance GL20-4AD and is the answer not in the manual?

Inovance GL20-4AD Specifications

General IconGeneral
BrandInovance
ModelGL20-4AD
CategoryControl Unit
LanguageEnglish

Related product manuals