MD380 User Manual Operation, Display and Application Example
- 81 -
4.17 Password Setting
7KH$&GULYHSURYLGHVWKHXVHUSDVVZRUGSURWHFWLRQIXQFWLRQ:KHQ)3LVVHWWRDQRQ
zero value, the password function is enabled. The password takes effect after you after exit
WKHIXQFWLRQFRGHHGLWLQJVWDWH:KHQ\RXSUHVV
PRG
again, "------" will be displayed, and
you must enter the correct user password to enter the menu.
To cancel the password protection function, enter the menu with the correct password and
then set FP-00 to 0.
4.18 Parameter Saving and Factory Parameter Restoring
$IWHUDIXQFWLRQFRGHLVPRGL¿HGRQWKHRSHUDWLRQSDQHOWKHPRGL¿FDWLRQZLOOEHVDYHGLQWKH
register of the AC drive and remain effective at next power-on.
The AC drive supports backup and restoration of parameter setting, which is convenient for
commissioning.
The AC drive also provides the retentive function on alarm information and accumulative
running time.
You can restore the backup values or factory parameters of the AC drive or clear the running
data through FP-01. For details, see the description of FP-01.
Figure 4-35 Parameter saving and default parameter restoring
Function parameters
working area during running
Function codes user
backup area
Register areas are
retentive at power down
Function codes
factory backup area
F9-14ĂF9-44: Fault record;
accumulative running time
(Default parameters)
(FP-01 4) + ENTER
(FP-01 501) + ENTER
Preset by
delivery
(FP-01 1)+ENTER
Restoring backup
parameters
Restore factory
parameters
Back up the current
user parameters
(Parameters that the user
needs to back up)
(FP-01 2) + ENTER
Clear recorded
information manually
Run after
power-on