Mounting the Device 5
3 Mounting the Device
1
Housing back panel
2
Wall
1a
3 drilled holes for screw mounting
3
Installed cable (in-wall)
1b
Cutout for installed cables (in-wall)
4
Cable feed for surface-mounted installation
Installation Site
The device is designed for fixed installation in dry rooms. Operation in humid environments is not
permitted.
Maintain a distance of 30 cm to other devices with RFID readers.
Mounting
Use the screws and screw anchors included in delivery to mount the device.