LED 2 Device status or error Description
Solid with one blink
Add node attempt failed because
node already in the network (lasts 60
seconds).
The device you attempted to add to
a network is already in a network
and must be deleted before it can
join a new network
LED L3 (yellow)
L3 flashes with every communication between the module and its radio unit in Idle Mode, and with every communication
with Alarm.com in Connected Mode. In PowerSave Mode, this LED flashes in unison with LED 2.
LED L4 (green)
L4 indicates the LTE signal level as a number of flashes (zero to five bars). The number of bars may not correspond to
the bars shown on your cell phone. A level of 5 bars is obtained only in the strongest signal conditions.
The signal level is updated every ten seconds if it fluctuates, or every 30 seconds if it is fairly stable.
If L4 is not flashing it indicates one of the following states:
The module is in PowerSave Mode.
The module just powered up.
There is no LTE coverage in the area. Alarm.com recommends a steady signal level of 2 or higher for proper
operation of the module.
In Connected Mode, the LED toggles on and off.
LED L5 (yellow)
L5 indicates Z-Wave errors.
LED flashes Device status or error Description
2-blink
No other nodes are in the network
(lasts until a device is added to the
network)
No devices have been added that
can be controlled by the LTE module
yet.
5-blink Learn mode error (lasts 60 seconds)
The device was not successfully
added to the Z- Wave network.
https://answers.alarm.com/ADC/Partner/Installation_and_Troubleshooting/Panels/Interlogix_Simon_XT/Interlogix_Simon_XT_…
Updated: Tue, 31 Mar 2020 20:51:49 GMT
12

Other manuals for Interlogix Simon XT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix Simon XT and is the answer not in the manual?

Interlogix Simon XT Specifications

Power IconPower
power requirements6V nominal
standby current30mA (10mA in PowerSave Mode)
peak current1.7 A
Operating Environment IconOperating Environment
operating temperature32 to 120°F (0 to 49°C)
storage temperature-30 to 140°F (-34 to 60°C)
max. relative humidity90% non-condensing