Dimensions (H x W) 4 1/16 x 1 7/8 in.
Compatibility
The LTE module is compatible with all Simon XT (version 1.3+), all XTi, and all XTi-5 control panels.
Account creation
Before installing an Alarm.com LTE Module in a Simon XT, XTi, or XTi-5 system, a new customer account needs to be
created with Alarm.com. It is recommended to create the account at least 24 hours in advance of installation to ensure
that the radio is activated prior to installation. For more information about creating a new customer account, see How to
Create an Alarm.com Customer Account.
To activate an account, see www.alarm.com/dealer and login. In Customers, click Create New Customer. The following
customer information is required to create the account:
Customer Address
Customer Phone Number
Customer E-mail
Preferred login name for the customer
Alarm.com Radio Serial Number
At the end of the account creation process, there is the option to print a Welcome Letter for the customer that has their
login information and temporary password for the Alarm.com website.
Note: At least one sensor must be learned into the panel to complete the new subscriber setup. If not all sensors and
touch screens were learned in before powering up the module, an updated sensor list must be requested by performing
an LTE phone test or requesting an updated equipment list from the Partner Portal.
Installation
The installation consists of inserting the module into the panel, attaching the antenna, and performing an LTE phone test
at the panel.
Follow these guidelines during installation:
Before affixing the panel to a wall, verify the LTE signal level at the installation location.
On the Simon XT panel, press and hold [5] for 10 seconds to view the LTE signal level.
With either panel, module LED L4 blinks to indicate signal strength. For more information, see LED details. An
installation location with a sustained signal level of two or more bars is recommended.
Do not exceed the panel total output power when using panel power for the LTE Module, hardwired sensors, and
/or sirens. Refer to the specific panel installation instructions for details.
Only one LTE Module can be used per Simon XT, XTi, or XTi-5 panel.
https://answers.alarm.com/ADC/Partner/Installation_and_Troubleshooting/Panels/Interlogix_Simon_XT/Interlogix_Simon_XT_…
Updated: Tue, 31 Mar 2020 20:51:49 GMT
2

Other manuals for Interlogix Simon XT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix Simon XT and is the answer not in the manual?

Interlogix Simon XT Specifications

Power IconPower
power requirements6V nominal
standby current30mA (10mA in PowerSave Mode)
peak current1.7 A
Operating Environment IconOperating Environment
operating temperature32 to 120°F (0 to 49°C)
storage temperature-30 to 140°F (-34 to 60°C)
max. relative humidity90% non-condensing
Dimensions IconDimensions
height4 1/16 in.
width1 7/8 in.